MP100S vs MP200 Comparison Table

MP100S and MP200 are compatible with every type of porcelain powder and the quality of work is the same. The biggest difference is that the MP100S has two vacuum valves, which provides functions such as interval vacuum and holding a constant, adjustable vacuum level.

On the MP200, some parameters that are very rarely used and not needed in practice have been removed from the program by assigning fixed values. It is simpler to use.

Its simple structure makes it more economical.

MP200 MP100S
Preheating Rate Fixed (80C/min) Adjustable ()
Interval Vacuum Single Valve (None) Dual Valve (Interval/Continuous)
Rapid Cooling None Vacuum-assisted rapid cooling
Vacuum Level None (Default 0 atm, 960 mmHg) Adjustable
Cooling Rate None Yes
Waiting During Cooling None Yes
Parameters MP 100S MP 200
Preheating Ramp Rate 20-70 °C/min Fixed 50°C/min
Preheat 200-500°C/min 200-500°C/min
Preheat Hold Time 0-99 min 0-99 min
Lift Closing Time 0-99 min (10 steps) 0-99 min (10 steps)
Drying Time 0-99 min 0-99 min
Target Temperature Preheat -1100 °C Preheat -1100 °C
Heating Rate 20-130 °C/min 20-130 °C/min
Vacuum Start Temperature 0-1100 °C 0-1100 °C
Vacuum End Temperature 400-1100 °C 400-1100 °C
Vacuum Hold Time 0-99 min 0-99 min
Cooling Temperature 0-Target Temperature °C None
Cooling Rate 0-50 °C/min Free Cooling
Cooling Hold 0-99 min None